Metering pumps and Mixers are used in various processes within municipal and industrial water and wastewater treatment. These products are critical in various treatment processes; such as disinfection, pH balance, filtration, coagulation, and flocculation. Reliable and accurate products enable water treaters to focus on the process at hand by trusting supporting equipment.
Coagulation and flocculation are both critical processes to separate and remove suspended solids in water and wastewater treatment. These processes improve the clarity of the water to reduce turbidity. Coagulation and flocculation pull out suspended solids that might take days or even decades to settle out of the water naturally.
Examples of water treatment before (right) and after (left) coagulation and flocculation treatment
Both processes require both physical agitation and coagulant chemicals to be added to the water treatment process. This optimizes the processing time, water quality, and cost of treatment.
Chemical addition in the coagulation and flocculation water treatment process using LMI Series G pumps.
Ultimately, the coagulation and flocculation processes turn murky water into clear water by accelerating the time it takes for particles to settle. Once these particles have settled, they can be filtered out.
Coagulation is this process that neutralizes the charged suspended solids in the water. As natural particles are typically negative, the coagulants, or positively charged chemicals are typically added to the process to neutralize charge.
Coagulants work by clumping together suspended particles by altering their electrical charge: it is a charge neutralization process. Envision a magnet: it is not possible to attach two “South” poles a magnet together as the similar charge creates a repelling force.
Similar to magnets, colloidal particles that carry the same charge repel each other. When millions of particles are repelling each other, water clarity is diminished. Neutralizing electrical charge allows the particles to clump together forming flocs.From this point the clumped particles can be filtered out of the water. However; the larger the flocs of particles, the easier it is to filter them. The process of increasing the size of flocs is known as flocculation.
When millions of particles repel each other, water clarity is diminished.
There are two different types of coagulants that are used: organic and inorganic. Inorganic coagulants, or inorganic salts, are usually a type of aluminum or iron salt. Aluminum sulfate, commonly known as alum, and ferric chloride are popular and widely used. However, in order to be effective, the coagulant must be applied and added to the process water properly.
Turbidity examples in Coagulation and Flocculation
Determining the amount and type of coagulant used changes based on a variety of process conditions. Many different external and environmental conditions impact how the raw water is treated which changes how much and what types of chemicals the treater must use. For example, a heavy rain will greatly impact the influent, or raw, water in a municipal treatment plant.
The jar test is a standard method in which various amounts of coagulant and flocculation times are tested on a raw water sample. There are multiple samples to test before implementation into a larger volume of the water treatment process.
Organic coagulants, also known as polymers are prevalently used in the water treatment processes. While polymers are more expensive by weight compared to inorganic coagulants, a lesser amount of chemical may be used.
Jar Testing different coagulation amounts and flocculation rates
Furthermore, the process of coagulation uses higher viscosity fluids to treat the water. There are typically two types of viscous fluids found in these processes: Netwonian and Thixotropic.
Newtonian fluids have a viscosity that does not change based on the mechanical stress applied to it while thixotropic fluids have viscosity that changes under the application of mechanical stress or shear. Thixotropic viscosity is also known as shear thinning, and the viscosity reduces over time as the fluid shears. For this reason, it is important to select a pump product that is compatible with higher viscosities.
While the coagulation process is exceptionally critical, it can also be costly. Costliness is primarily determined by how much chemical is used in the process. While polymer may be more expensive by weight, it can be more efficient than an inorganic salt. Polymer efficacy can be increased by preparing the proper polymer volume to ensure it can fully react with the process water, which in turn reduces polymer usage and may have a cost advantage over the inorganic salt.
Inorganic chemicals require the water treatment operator to strike a balance which requires accurate dosing of chemicals. Too much chemical would likely require pH correction; while not enough chemical may lead to additional processing time to reach the desired condition.
Coagulation processes are time intensive and for that reason can be expensive. It is important for water treatment plants to optimize their process with cost effective technologies. Measurement devices such as Streaming Current Detectors measure net charge density of particles in a sample of water. These devices help improve and streamline coagulation processes because it measures in real time how well the process is working.
Additionally, flash mixing can be a major constraint for agitators in coagulation processes. Flash mixing in the coagulation process requires vigorous flow in a very short time period, typically less than one minute. For this reason, it is important to select a suitable motor and impeller to achieve the desired results.
While coagulation is primarily a chemical process; flocculation is the clumping of particles primarily via a physical process. Once the coagulation process has taken place, the flocculation process begins with agitation or mixing of the fluid. This allows some of the suspended solids to begin to bond together and grow in size into larger clumps. This process is assisted by the addition of flocculants and mixers.
After the colloidal particles have had their charge neutralized, mixing of the process fluid allows more of these particles to come together. The goal of this process is for the grouped particles to achieve a state in which they can be most easily filtered out of the water.
Mixing of the process water with the addition of adding flocculants allows for the colloidal particles to stick and form bigger and bigger clumps. The challenge with this process is that you must stir the fluid without separating the particles. For this reason, it is important to consider the mixing shear on the fluid.
Different flocculation rates are being measured to optimize the flocculation process at a larger scale
LMI has a global network of chemical feed and application experts that help water treatment professionals improve their operations. Additionally, LMI produces reliable and accurate chemical feed pumps and provides reliable mixers for these particular applications. By utilizing LMI’s network of experts and products, water treatment plants can reduce their costs and improve their processes.
What is Flocculation and Coagulation?
Flocculation and Coagulation is the process used to thicken a fluid. Sometimes these terms are used interchangeably
What is the difference between Coagulation and Flocculation?
Coagulation is primarily a chemical process to thicken fluid and flocculation is primarily a mechanical process.
What comes first: Flocculation or Coagulation?
Typically, coagulation is first and flocculation is second.
What are Coagulants and Flocculants?
Coagulants and Flocculants are agents that assist in the thickening of particles in water to be more easily filtered out in a subsequent process.
Is alum a coagulant or a flocculant?
Alum is a coagulant, in fact, one of the most widely used coagulants. Sometimes coagulation and flocculation terms are used interchangeably.
Is gypsum a flocculant?
Like, Alum, Gypsum would be classified as a coagulant; however, flocculants and coagulants are sometimes used synonymously. Gypsum is usually only used in specific applications.